Performance Data Sheet
AWF5524EXG
General Information
Model AWF5524EXG Refrigerant R-22
Test Condition ARI Performance Test Voltage 460V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 5870 4830
Watts 964 920
Amps 1.76 1.73
-15
Lb/h 75.3 65.0
Btu/h 7630 6500 5420
Watts 1060 1030 1000
Amps 1.87 1.85 1.83
-10
Lb/h 97.5 86.7 75.9
Btu/h 9480 8260 7080 5940
Watts 1150 1130 1120 1110
Amps 1.97 1.96 1.95 1.95
-5
Lb/h 121 109 97.9 86.3
Btu/h 11400 10100 8840 7590 6370
Watts 1230 1230 1230 1230 1240
Amps 2.06 2.06 2.07 2.08 2.08
0
Lb/h 145 133 121 109 95.8
Btu/h 13500 12100 10700 9340 8000
Watts 1310 1320 1330 1350 1370
Amps 2.14 2.16 2.18 2.20 2.22
5
Lb/h 170 158 145 133 119
Btu/h 15800 14200 12700 11200 9750 8320 6900
Watts 1370 1400 1430 1460 1490 1510 1520
Amps 2.21 2.24 2.28 2.32 2.35 2.38 2.41
10
Lb/h 197 185 171 158 144 128 112
Btu/h 18200 16500 14900 13200 11600 10100 8510
Watts 1430 1470 1520 1570 1620 1650 1670
Amps 2.27 2.32 2.37 2.43 2.48 2.53 2.57
15
Lb/h 226 213 199 185 170 154 137
Btu/h 20900 19000 17200 15400 13700 12000 10300
Watts 1480 1540 1600 1670 1730 1780 1820
Amps 2.31 2.38 2.46 2.53 2.60 2.66 2.72
20
Lb/h 257 243 229 214 198 182 164