Performance Data Sheet
AKA9455EXD
General Information
Model AKA9455EXD Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 9870 8700 7730 6900 6170 5500 4840
Watts 727 829 894 935 963 990 1030
Amps 4.30 4.39 4.52 4.66 4.79 4.90 4.97
20
Lb/h 123 112 103 95.7 89.6 83.8 77.6
Btu/h 10600 9500 8570 7770 7050 6360 5670
Watts 740 851 925 975 1010 1050 1100
Amps 4.31 4.47 4.64 4.82 4.99 5.13 5.22
25
Lb/h 131 121 113 107 102 96.1 90.0
Btu/h 11600 10500 9570 8770 8030 7310 6560
Watts 751 869 951 1010 1060 1110 1170
Amps 4.32 4.52 4.74 4.97 5.17 5.34 5.46
30
Lb/h 142 133 126 120 115 110 103
Btu/h 12700 11600 10700 9900 9120 8340 7510
Watts 761 885 975 1040 1100 1150 1230
Amps 4.31 4.57 4.84 5.10 5.34 5.54 5.68
35
Lb/h 154 146 140 135 130 124 117
Btu/h 14000 13000 12000 11100 10300 9440 8510
Watts 770 901 996 1070 1130 1200 1280
Amps 4.29 4.60 4.91 5.22 5.49 5.72 5.89
40
Lb/h 169 162 156 151 145 139 132
Btu/h 15500 14400 13400 12500 11600 10600 9540
Watts 781 916 1020 1100 1170 1240 1330
Amps 4.26 4.62 4.98 5.32 5.63 5.89 6.08
45
Lb/h 186 179 173 168 162 156 147
Btu/h 17200 16100 15000 14000 12900 11800 10600
Watts 794 933 1040 1120 1200 1280 1370
Amps 4.22 4.62 5.03 5.41 5.76 6.05 6.26
50
Lb/h 205 198 192 186 180 172 163
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 3.741831E+04 -2.754706E+03 8.956218E+00 4.904992E+02
C2 -4.579609E+02 -6.999511E+00 -1.117245E-01 -6.966010E+00