Performance Data Sheet
AEA4448YXD
General Information
Model AEA4448YXD Refrigerant R-134a
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSIR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 3430 3240 3000 2730 2440 2180 1960
Watts 548 559 572 586 599 612 622
Amps 4.46 4.56 4.63 4.68 4.71 4.74 4.78
20
Lb/h 45.0 44.2 42.7 40.7 38.7 36.8 35.3
Btu/h 3820 3650 3410 3120 2810 2520 2250
Watts 571 586 603 619 635 649 660
Amps 4.53 4.63 4.70 4.75 4.79 4.82 4.86
25
Lb/h 50.0 49.8 48.6 46.8 44.8 42.6 40.8
Btu/h 4270 4100 3850 3550 3210 2880 2560
Watts 589 609 629 649 667 683 695
Amps 4.63 4.73 4.80 4.85 4.89 4.93 4.97
30
Lb/h 55.8 56.0 55.2 53.5 51.3 48.9 46.6
Btu/h 4790 4610 4350 4020 3650 3260 2890
Watts 605 630 654 677 697 715 728
Amps 4.74 4.85 4.92 4.97 5.01 5.05 5.10
35
Lb/h 62.4 63.1 62.5 60.9 58.6 55.8 52.9
Btu/h 5370 5180 4890 4530 4120 3680 3250
Watts 621 650 678 704 727 747 762
Amps 4.87 4.97 5.04 5.09 5.13 5.18 5.23
40
Lb/h 70.1 71.2 70.7 69.1 66.5 63.3 59.8
Btu/h 6020 5820 5500 5100 4640 4150 3640
Watts 636 670 703 732 758 780 797
Amps 4.98 5.08 5.16 5.21 5.25 5.30 5.36
45
Lb/h 78.9 80.3 80.0 78.2 75.4 71.7 67.5
Btu/h 6750 6530 6180 5730 5210 4650 4070
Watts 654 693 730 763 793 817 835
Amps 5.09 5.19 5.26 5.32 5.36 5.41 5.47
50
Lb/h 89.0 90.6 90.3 88.4 85.2 81.0 76.1
Btu/h 7570 7310 6920 6430 5850 5210 4540
Watts 677 721 762 799 831 858 878
Amps 5.17 5.27 5.34 5.40 5.45 5.50 5.56
55
Lb/h 100 102 102 99.9 96.3 91.5 85.7
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - Performance Data Sheet

Performance Data SheetAEA4448YXDGeneral InformationModel AEA4448YXD Refrigerant R-134aTest Condition ARI Performance Test Voltage 230V ~ 60HZReturn Ga

Pagina 2 - Tc = Condensing Temperature

COEFFICIENTS CAPACITY POWER CURRENT MASS FLOWC1 9.907326E+02 6.764646E+02 1.291199E+00 2.582897E+01C2 -9.627301E+01 1.942748E+00 -2.617554E-02 -2.1073