Performance Data Sheet
TPA9421YXA
General Information
Model TPA9421YXA Refrigerant R-134a
Test Condition ARI Performance Test Voltage 115V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSIR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 3060 2850 2650 2450 2240 2030 1820
Watts 368 382 395 409 421 433 445
Amps 6.32 6.37 6.43 6.49 6.55 6.61 6.67
20
Lb/h 40.4 39.2 38.0 36.8 35.5 34.3 33.2
Btu/h 3500 3270 3030 2800 2560 2320 2080
Watts 386 401 416 431 446 460 473
Amps 6.34 6.41 6.48 6.56 6.63 6.70 6.77
25
Lb/h 46.1 44.7 43.3 42.0 40.6 39.2 37.8
Btu/h 3980 3710 3440 3170 2900 2640 2360
Watts 406 422 438 455 471 487 502
Amps 6.38 6.47 6.56 6.65 6.74 6.83 6.91
30
Lb/h 52.4 50.9 49.3 47.8 46.2 44.7 43.1
Btu/h 4480 4180 3880 3580 3280 2980 2680
Watts 429 445 462 480 497 514 532
Amps 6.46 6.57 6.67 6.78 6.88 6.98 7.08
35
Lb/h 59.2 57.6 55.9 54.2 52.5 50.8 49.1
Btu/h 5020 4690 4350 4020 3680 3350 3020
Watts 454 471 489 506 525 543 562
Amps 6.56 6.69 6.81 6.93 7.05 7.17 7.29
40
Lb/h 66.5 64.8 63.0 61.2 59.4 57.6 55.7
Btu/h 5600 5220 4850 4490 4120 3750 3390
Watts 483 500 518 536 555 574 594
Amps 6.70 6.84 6.97 7.11 7.25 7.38 7.52
45
Lb/h 74.3 72.5 70.7 68.8 66.9 64.9 62.9
Btu/h 6200 5800 5390 4990 4580 4180 3780
Watts 516 532 550 568 587 607 627
Amps 6.85 7.01 7.17 7.32 7.47 7.63 7.78
50
Lb/h 82.5 80.7 78.8 76.9 74.8 72.8 70.7
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.160090E+03 2.404105E+02 6.557296E+00 2.886343E+01
C2 1.138191E+02 1.092855E-01 -4.744141E-02 8.365702E-01