COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 6.856077E+03 -1.446708E+03 -2.031889E+00 8.177849E+01
C2 2.252290E+02 -5.460992E+00 2.738592E-02 3.054527E+00
C3 -1.156345E+02 4.716599E+01 1.221510E-01 -1.644010E+00
C4 7.067369E-01 -1.125661E-01 -1.930496E-03 -4.376246E-03
C5 -1.960110E+00 1.707676E-01 6.738317E-04 -2.458728E-02
C6 9.478213E-01 -4.069310E-01 -1.104976E-03 1.602187E-02
C7 3.143653E-02 1.727589E-04 7.306134E-06 5.549966E-04
C8 -2.432013E-02 5.701042E-04 8.303527E-06 -2.829947E-04
C9 1.097733E-02 -4.705406E-04 -3.524224E-06 1.636385E-04
C10 -3.555852E-03 1.160212E-03 3.318076E-06 -6.311144E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature